Indirect-heating boiler

With two coils

Two heat sources on one tank

Two independent coils let you connect two heat sources to a single tank — for example a boiler and a solar collector or heat pump. The lower coil heats the whole volume and removes the legionella risk.

With two coils
160—5000L
Volume
13
Models
6bar
Vessel
10bar
Coil
2
Coils
Design

Two heat sources on one tank

01

Two coils

Separate circuits N2–N4 and N5–N6 — two heat sources on one tank.

02

Legionella protection

The low coil position heats the entire volume of the vessel.

03

Recirculation-ready

Port N3 — hot water reaches the tap without waiting.

04

High thermal insulation

42 kg/m³ HCFC-free polyurethane foam and a Termowen outer jacket.

Model range · Volume, litres
160
200
300
400
500
800
1000
1500
2000
2500
3000
4000
5000
Technical parameters

Technical parameters

The full model range. The table scrolls horizontally.

ModelVMEX 160VMEX 200VMEX 300VMEX 400VMEX 500VMEX 800VMEX 1000VMEX 1500VMEX 2000VMEX 2500VMEX 3000VMEX 4000VMEX 5000
VolumeV (L)1602003004005008001000150020002500300040005000
DiameterD (mm)590590590750750950950112012601460146017101710
HeightH (mm)1060130018101380162016702010225022502200260026003000
Water inlet / outletN1–N7 (in)¾″¾″1″1″1″1¼″1¼″1¼″1¼″1½″1½″2″2″
Coils inlet / outletN2–N4 · N5–N6 (in)1″1″1″1″1″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
RecirculationN3 (in)¾″¾″1″1″1″1¼″1¼″1¼″1¼″1½″1½″2″2″
Magnesium anodeN8 (in)1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
ThermometerN9 (in)½″½″½″½″½″½″½″½″½″½″½″½″½″
Inspection hatchN11 (in)4″4″4″4″4″5″5″5″5″5″5″5″5″
DrainN12 (in)1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
Dry weightW (kg)59891081151602473004105836787909751240

We'll match the equipment to your project

Send us your boiler-room parameters — we'll suggest a model, size the output and prepare a commercial offer.