Indirect-heating boiler

Combined

Two heating circuits in one vessel

The first circuit is a coil of seamless Ø32×3 tube, the second is an electric heating element. The control panel with an indicator board and built-in safety system switches circuits automatically: the boiler heats water in the heating season, the element in the off-season.

Combined
100—5000L
Volume
14
Models
6bar
Vessel
10bar
Coil
2
Circuits
Design

Two heating circuits in one vessel

01

Coil Ø32×3

The first circuit — a seamless tube rated for a working pressure of 10 bar.

02

Electric element

The second circuit works independently when the boiler is off.

03

Control panel

An indicator board with a built-in safety system.

04

Steel or stainless

A body of high-grade or stainless steel, to your choice.

Model range · Volume, litres
100
160
200
300
400
500
800
1000
1500
2000
2500
3000
4000
5000
Technical parameters

Technical parameters

The full model range. The table scrolls horizontally.

ModelVMEX 100VMEX 160VMEX 200VMEX 300VMEX 400VMEX 500VMEX 800VMEX 1000VMEX 1500VMEX 2000VMEX 2500VMEX 3000VMEX 4000VMEX 5000
VolumeV (L)1001602003004005008001000150020002500300040005000
DiameterD (mm)4905905905907507509501100130014001460146017101710
HeightH (mm)10301060130018101380162016701900190019002200260025003000
Water inlet / outletN1–N2 (in)¾″¾″¾″1″1″1″1¼″1¼″1¼″1¼″1½″1½″2″2″
Coil inlet / outletN3–N4 (in)1″1″1″1″1″1″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
RecirculationN5 (in)¾″¾″¾″1″1″1″1¼″1¼″1¼″1¼″1½″1½″2″2″
Magnesium anodeN6 (in)1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
Auxiliary electric heater (kW)4060608080100100120120120160180180200
ThermometerN8 (in)½″½″½″½″½″½″½″½″½″½″½″½″½″½″
Inspection hatchN9 (in)4″4″4″4″4″4″5″5″5″5″5″5″5″5″
DrainN10 (in)1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″1¼″
Dry weightW (kg)536381991171391922403354706657108851005